Page 24 - Lockwell Industrial Catalogue
P. 24
MS116, MS132, MS165, MO132, MO165, MS132-T
Main accessories
Ordering details
Suitable for Rated control supply voltage Type
Order code
1SAM201910R1001 1SAM201910R1002 1SAM201910R1003 1SAM201910R1004
1SAM201904R1010 1SAM201904R1001 1SAM201904R1002 1SAM201904R1003 1SAM201904R1004 1SAM201904R1008 1SAM201904R1005 1SAM201904R1006 1SAM201904R1007 1SAM201904R1009
Pkg Weight qty (1 pce)
pcs kg
1 0.100 1 0.100 1 0.100 1 0.100
1 0.100 1 0.100 1 0.100 1 0.100 1 0.100 1 0.100 1 0.100 1 0.100 1 0.100 1 0.100
UA1-24
T16
T16 + DB16
– Manual or automatic reset selectable
– Phase loss sensitive acc. to IEC/EN 60947-4-1
– TEST and STOP function – Trip indication on the front – Temperature compensation
– Suitable for three- and single-phase applications
Ordering details
Setting range Short-circuit Trip class Type protective device
Order code
Weight
(1 pce)
24
50 Hz
V AC
Shunt trips – mountable on the left
60 Hz
V AC
20 ... 24 AA1-24 110 AA1-110 200 ... 240 AA1-230 350 ... 415 AA1-400
MS116, MS132, MS165, MO132, MO165, MS132-T
20 ... 24 110
200 ... 240 350 ... 415
AA1-24 Undervoltage releases – mountable on the left
MS116, MS132, 20 24 UA1-20
MS165, MO132, MO165, MS132-T
24 - UA1-24 48 - UA1-48 60 - UA1-60 110 120 UA1-110 - 208 UA1-208 230 240 UA1-230 400 - UA1-400 415 480 UA1-415 - 575 UA1-575
T16 thermal overload relays – 0.10 to 16.0 A
Ordering details
Description
The T16 thermal overload relays are economic electromechanical protection devices for the main circuit. They offer reliable protection for motors in the event of overload or phase failure. The devices have trip class 10. The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a change of the contacts switching position (95-96 / 97-98).
A kg
0.10 ... 0.13 0.13 ... 0.17 0.17 ... 0.23 0.23 ... 0.31 0.31 ... 0.41 0.41 ... 0.55 0.55 ... 0.74 0.74 ... 1.00 1.00 ... 1.30 1.30 ... 1.70 1.70 ... 2.30 2.30 ... 3.10 3.10 ... 4.20 4.20 ... 5.70 5.70 ... 7.60 7.60 ... 10.0 10.0 ... 13.0 13.0 ... 16.0
0.5 A, fuse type T 10 1.0 A, fuse type T 10 1.0 A, fuse type T 10 1.0 A, fuse type T 10 2.0 A, fuse type gG 10 2.0 A, fuse type gG 10 4.0 A, fuse type gG 10 6.0 A, fuse type gG 10 6.0 A, fuse type gG 10 10.0 A, fuse type gG 10 10.0 A, fuse type gG 10 10.0 A, fuse type gG 10 20.0 A, fuse type gG 10 20.0 A, fuse type gG 10 35.0 A, fuse type gG 10 35.0 A, fuse type gG 10 40.0 A, fuse type gG 10 40.0 A, fuse type gG 10
T16-0.13 1SAZ711201R1005 T16-0.17 1SAZ711201R1008 T16-0.23 1SAZ711201R1009 T16-0.31 1SAZ711201R1013 T16-0.41 1SAZ711201R1014 T16-0.55 1SAZ711201R1017 T16-0.74 1SAZ711201R1021 T16-1.0 1SAZ711201R1023 T16-1.3 1SAZ711201R1025 T16-1.7 1SAZ711201R1028 T16-2.3 1SAZ711201R1031 T16-3.1 1SAZ711201R1033 T16-4.2 1SAZ711201R1035 T16-5.7 1SAZ711201R1038 T16-7.6 1SAZ711201R1040 T16-10 1SAZ711201R1043 T16-13 1SAZ711201R1045 T16-16 1SAZ711201R1047
0.100 0.100 0.100 0.100 0.100 0.100 0.100 0.100 0.100 0.100 0.100 0.100 0.100 0.100 0.100 0.104 0.104 0.104
2CDC231025F0013 2CDC231009F0013
CONTROL