Page 165 - Lockwell Industrial Catalogue
P. 165

          INTERMEDIATE METERING
FUNCTIONS AND CHARACTERISTICS
          PM8000 series
Technical specifications
Electrical characteristics
Type of measurement
Current & voltage
True rms to 256 samples per cycle
Class 0.2 as per IEC 61557-12
Class 0.2 as per IEC 61557-12
Class 0.5 as per IEC 61557-12
Class 0.2 as per IEC 61557-12
Class 0.2S IEC 62053-22 (In=5A)
Class 0.2 IEC 61557-12, ANSI C12.20 Class 0.2
Class 0.5S IEC 62053-24*
EN50470-1, EN50470-1, AnnexB & AnnexD (optional model)
1/2 cycle or 1 second
57 VLN/100 VLL to 400 VLN/690 VLL
5 MΩ per phase
42 to 69Hz (50/60Hz nominal)
20 to 450Hz
1A (0.5S), 5A (0.2S) , 10A (0.2 ANSI)
Starting Current: 5mA Accurate Range: 50mA - 10A
200 A rms for 0.5s, non-recurring
0.0003 Ω per phase 0.024 VA at 10A
90-415 V AC ±10% (50/60Hz ± 10%) 120-300 V DC ±10%
100 ms (6 cycles at 60 Hz) min., any condition 200 ms (12 cycles at 60 Hz) typ., 120 V AC 500 ms (30 cycles at 60 Hz) typ., 415 V AC
Meter Only: 18 VA max at 415V AC, 6W at 300V DC
Fully optioned meter: 36 VA max at 415V AC, 17W at 300V DC.
3 form A digital inputs (30V AC/60 V DC)
1 form A (KY) solid state digital output (30V AC/60 V DC, 75mA).
Digital - 6 form A digital inputs (30V AC / 60V DC) wetted + 2 form C relay outputs (250VAC, 8A) Analogue - 4 analogue inputs (4-20mA, 0-30Vdc) + 2 analogue outputs (4-20mA, 0-10Vdc).
Integrated Display Model 0.581 kg DIN rail mounted Model 0.528 kg IO modules 0.140 kg
Remote display 0.300 kg
IP 54, UL type 12: Panel mount and Remote display, front. IP 30: Panel mount rear, DIN rail mount, I/O modules.
96 x 96 x 77.5 mm 90.5 x 90.5 x 90.8 mm 96 x 96 x 27 mm
90.5 x 90.5 x 22 mm
-25oC to +70oC
-25oC to +60oC
-40oC to +85oC
5% to 95% non-condensing III
3000m above sea level
                       Measurement accuracy
Data update rate
Input-voltage characteristics
Input-current characteristics
Power supply
Input/outputs
Active Power Power factor Frequency
Active energy
Reactive Energy MID Directive
Specified accuracy voltage Impedance
Specified accuracy frequency - Frequency
Limit range of operation - frequency
Rated nominal current
Specified accuracy current range
Permissible overload Impedance
Burden
AC
DC
Ride-through time
Burden
Meter Base Only
Optional
                                                                 Mechanical characteristics
Weight
IP degree of protection Dimensions
Environmental conditions
Operating temperature
Remote Display Unit
Storage temperature
Humidity rating
Installation category
Operating altitude (maximum)
          Panel mount model
   DIN model
   Remote display
   IO modules
                           schneider-electric.co.uk/metering
59
Can't see what you need? Our experts can help! 165
 ENCLOSURES & PANEL PRODUCTS

















   163   164   165   166   167