Page 140 - Lockwell Industrial Catalogue
P. 140
Actuators
AZM300
Part number Guard Type
Diagnostic
3 different directions of actuation
AZ/AZM300-B1 Hinged & Sliding Guards
NOTE: Non-Coded versions are available as standard. Versions with I2 are available on request.
Magnetic Locking Device
MZM100
Rectangular housing with RFID technolgy. Operating condition identified with 3 x LEDs. 24vDC. Coding level “High” according to ISO 14119.
Other varients available. Please contact your local Lockwell branch.
Applications & Functions
• Automaticlatching
• Innovativeanduniqueoperatingprinciple
• Electrically adjustable latching force 30N - 100N
• Monitored clamping force: Typically 750N Gguaranteed 500N
• Electronic contact-free, coded system
• Connector M12, 8-pole
Part number
MZM 100 ST2-1P2PWRE-A
MZM 100 ST2-1P2PWREM-A
Guard Type
Hinged & Sliding Guards
Hinged & Sliding Guards
Diagnostic
2 x safety inputs. 2 x safety outputs. Diagnostic signal = Guard Door Closed.
2 x safety inputs. 2 x safety outputs. Diagnostic signal = Guard Door Closed.
Clamp Force
500N Guaranteed
500N Guaranteed
Part number
AZM400Z-ST-1P2P
AZM400Z-ST-I2-1P2P
Guard Type
Sliding Guards
Sliding Guards
Supply Voltage
24VDC
24VDC
Safety Classification
PL e / cat. 4 / SIL 3 for interlocking and guard locking function
PL e / cat. 4 / SIL 3 for interlocking and guard locking function
Diagnostic
2 x safety outputs. 2 x control inputs (to unlock) 1 x diagnostic signal
1 Diagnostic output The short-circuit proof diagnostic output OUT can be used for central visualisation or control tasks, e.g. in a PLC.
(The diagnostic output is not a safety-relevant output!)
Actuators
MZM100
Part number
Actuator
AZM400
Part number
MZM 100-B1.1
AZM400-B1
140
Safety Sensors
AZM400
Smart diagnostic by means of 3-colour LED’s. Red - Fault / Yellow - Device condition / Green - Supply voltage. Clamping force 10.000N. Coding level “High” according to ISO 14119.
Other varients available. Please contact your local Lockwell branch.
Applications & Functions
• MotorDrivenLockingSystem
• Bi-Stable
• Individual Actuator Coding with I2 version
• The teach in process can be repeated
• ConnectorPlug
• Cable supplied seperately
SAFETY