Page 139 - Lockwell Industrial Catalogue
P. 139

            Solenoid Locking Devices
RSS series
Rectangular housing with RFID technolgy. Operating condition identified with 3 x LEDs. 24vDC. Coding level “High” according to ISO 14119.
Other varients available. Please contact your local Lockwell branch.
Applications & Functions
• Individual Actuator Coding with I2 version
• The teach in process can be repeated
• ConnectorPlug
• Cable supplied seperately
• PowertoRelease
• Coding level “High” according to ISO 14119
Sensing
Latching/Non Safety Distance Direction of Supply
Partnumber Latching Classification Diagnostic (on/off) Actuation Voltage
               Solenoid Locking Devices
AZM300
Rectangular housing with RFID technolgy. Operating condition identified with 3 x LEDs. 24v.DC Coding level “High” according to ISO 14119.
Other varients available. Please contact your local Lockwell branch.
    RSS16-D-R-SK
RSS16-I2-D- R-ST
RSS16-D-SK
RSS 16-I2-D-ST
Latching
Latching
Non-Latching
Non-Latching
Ple Cat4 (ISO13849-1)
Ple Cat4 (ISO13849-1)
Ple Cat4 (ISO13849-1)
Ple Cat4 (ISO13849-1)
2 x safety intputs. 2 x safety outputs. 1 x semi-conductor output (signal)
Conventional. 2 x OSSD. 1 x Diagnostic
2 x safety intputs. 2 x safety outputs. 1 x semi-conductor output (signal)
Conventional. 2 x OSSD. 1 x Diagnostic
5mm/30mm
10mm / 20mm
5mm/30mm
10mm / 20mm
3 different directions of actuation
3 different directions of actuation
3 different directions of actuation
3 different directions of actuation
24VDC
24VDC
24VDC
24VDC
    NOTE: Non-Coded versions are available as standard. Versions with I2 are available on request.
 Solenoid Locking Devices
AZM 201
Rectangular housing with RFID technolgy. Operating condition identified with 3 x LEDs. 24vDC. Coding level “High” according to ISO 14119.
Other varients available. Please contact your local Lockwell branch.
   Applications & Functions
• Individual Actuator Coding with I2 version
• The teach in process can be repeated
• ConnectorPlug
• Cable supplied seperately
• PowertoRelease
• Coding level “High” according to ISO 14119
Part number
AZM201Z-SK-T-1P2PW
AZM201Z-I2-SK-T-1P2PW
Latching/Non Latching
Power to Release
Power to Release
Diagnostic
Interlocking Function up tp Ple CAT4. Guard Locking Function up to PLd CAT2 (ISO13849-1)
Interlocking Function up to Ple CAT4. Guard Locking Function up to PLd CAT2 (ISO13849-1)
Supply Voltage
24VDC
24VDC
Can't see what you need? Our experts can help! 139
Actuators
AZM 201
Part number
AZ/AZM201-B1-LT
AZ/AZM201-B1-RT
AZ/AZM201-B30-RTAG1P1
AZ/AZM201-B30-LTAG1P1
Guard Type
Sliding Guards
Sliding Guards
Right Hinged Guards
Left Hinged Guards
Applications & Functions
• Individual Actuator Coding with I2 version
• The teach in process can be repeated
• ConnectorPlug
• Cable supplied seperately
• PowertoRelease
• Coding level “High” according to ISO 14119
Part number
AZM300Z-ST- 1P2P
AZM300Z-I2- ST-1P2P
AZM300B-ST- 1P2P
AZM300B-I2- ST-1P2P
Guard Type
Hinged & Sliding Guards
Hinged & Sliding Guards
Hinged & Sliding Guards
Hinged & Sliding Guards
Safety Classification
Ple Cat4 (ISO13849-1)
Ple Cat4 (ISO13849-1)
Ple Cat4 (ISO13849-1)
Ple Cat4 (ISO13849-1)
Diagnostic
2 x safety inputs. 2 x safety outputs. Diagnostic signal = Guard Door Closed and Interlocking Device Locked.
1 Diagnostic output, p-type and 2 Safety outputs, p-type
2 x safety inputs. 2 x safety outputs. Diagnostic signal = Guard Door Closed and Interlocking Device Locked.
1 Diagnostic output, p-type and 2 Safety outputs, p-type
Signals
guard door closed and interlocking device locked
guard door closed and interlocking device locked
guard door closed and interlocking device locked
Monitoring
Solenoid Monitoring
Solenoid Monitoring
Actuator Monitoring
Actuator Monitoring
Supply Voltage
24VDC
24VDC
24VDC
24VDC
      NOTE: Non-Coded versions are available as standard. Versions with I2 are available on request.