Page 70 - Lockwell Industrial Catalogue
P. 70

                     THERMAL-MAGNETIC FUSEHOLDERS CIRCUIT-BREAKERS
 Fuse carriers ‘TeSys DF’
   Thermal - Magnetic Circuit - Breakers
    • • • •
For protecting and isolating control circuits
1 and 2 pole options
12 ratings available from 0.5 to 20 amps
Magnetic trip threshold between 12 and 16 In to withstand current peaks
Type
Single pole with trip threshold 12 to 16 x In
Single pole with trip threshold 12 to 16 x In
Single pole with trip threshold 12 to 16 x In
Single pole with trip threshold 12 to 16 x In
Single pole with trip threshold 12 to 16 x In
Single pole with trip threshold 12 to 16 x In
Single pole + neutral with trip threshold 12 to 16 x In
Single pole + neutral with trip threshold 12 to 16 x In
Single pole + neutral with trip threshold 12 to 16 x In
Single pole + neutral with trip threshold 12 to 16 x In
Single pole + neutral with trip threshold 12 to 16 x In
Single pole + neutral with trip threshold 12 to 16 x In
Single pole + neutral with trip threshold 12 to 16 x In
Single pole + neutral with trip threshold 12 to 16 x In
Single pole + neutral with trip threshold 12 to 16 x In
Single pole + neutral with trip threshold 12 to 16 x In
Single pole + neutral with trip threshold 12 to 16 x In
Double pole with trip threshold 12 to 16 x In
Double pole with trip threshold 12 to 16 x In
Double pole with trip threshold 12 to 16 x In
Double pole with trip threshold 12 to 16 x In
Double pole with trip threshold 12 to 16 x In
Double pole with trip threshold 12 to 16 x In
Double pole with trip threshold 12 to 16 x In
Double pole with trip threshold 12 to 16 x In
Thermal Rat- ing (Amps)
1
2
4
5
6
10
1
2
3
4
5
6
8
10
12
16
20
1
2
4
6
10
12
16
20
Magnetic Trip Current (Amps)
14
26
52
66
83
138
14
26
40
52
66
83
108
138
165
220
270
14
26
52
83
138
165
220
270
Part No.
GB2CB06
GB2CB07
GB2CB09
GB2CB10
GB2CB12
GB2CB16
GB2CD06
GB2CD07
GB2CD08
GB2CD09
GB2CD10
GB2CD12
GB2CD14
GB2CD16
GB2CD20
GB2CD21
GB2CD22
GB2DB06
GB2DB07
GB2DB09
GB2DB12
GB2DB16
GB2DB20
GB2DB21
GB2DB22
• • • •
NF C or DIN style fuse holders From 1 to 125 amps
1, 2, 3 & 4 pole options
Very compact to save space
Thermal Rating Amps
25 amps thermal rating
25 amps thermal rating
25 amps thermal rating
30 amps thermal rating
32 amps thermal rating
32 amps thermal rating
32 amps thermal rating
32 amps thermal rating
32 amps thermal rating
32 amps thermal rating
32 amps thermal rating
50 amps thermal rating
50 amps thermal rating
50 amps thermal rating
50 amps thermal rating
125 amps thermal rating
125 amps thermal rating
Description
8.5 x 31.5mm cartridge fuse or link
8.5 x 31.5mm cartridge fuse or link
8.5 x 31.5mm cartridge fuse or link
Class CC cartridge fuse or link
10 x 38mm cartridge fuse or link
10 x 38mm cartridge fuse or link
10 x 38mm cartridge fuse or link
10 x 38mm cartridge fuse or link
10 x 38mm cartridge fuse or link
10 x 38mm cartridge fuse or link
10 x 38mm cartridge fuse or link
14 x 51mm cartridge fuse or link
14 x 51mm cartridge fuse or link
14 x 51mm cartridge fuse or link
14 x 51mm cartridge fuse or link
22 x 58mm cartridge fuse or link
22 x 58mm cartridge fuse or link
No. of Poles
Neutral pole
1 Pole
3 Pole
3 Pole (For North American market)
Part No.
DF10N
DF81
DF83
DFCC3V
DF101
DF101N
DF101NV
DF102
DF103
DF103N
DF103NV
DF14N
DF141
DF141V
DF143C
DF22N
DF223C
                             ACCESSORIES
1 Pole +
3 Pole +
1 Pole
1 Pole + N
N with blown fuse indication
2 Pole
3 Pole
3 Pole + N
N with blown fuse indication
     Neutral pole
1 pole
1 Pole with fuse blown indication
3 Pole
Neutral pole
3 Pole
          Fuse Carrier Assembly Kits
 Fuse carrier to be assembled
DF8
DF10
DF14
Kit Contents
1 Pin
1 Pin
1 Pin
2 Clips
2 Clips
3 Clips
Part No.
DF8AP
DF10AP
DF14AP
 Accessories
Description Characteristics Part No.
    Thermal magnetic circuit breakers Busbar to supply 10 GB2DB or 20 GB2CB GB2G210
   70
CONTROL
   68   69   70   71   72