                    MAGNETIC MOTOR CIRCUIT-BREAKER
 Accessories
Description
Fault signalling contact + instantaneous contact
Fault signalling contact + instantaneous contact
Fault signalling contact + instantaneous contact
Fits within front of GV2 or GV3
Fits within front of GV2 or GV3
Fits within front of GV2 or GV3
Fits within front of GV2 or GV3
Fits within front of GV2 or GV3
Fits within front of GV3
Fits on LH side of GV2 or GV3
Fits on LH side of GV2 or GV3
Fits on LH side of GV2 or GV3
Fits on LH side of GV2 or GV3
Fits on LH side of GV2 or GV3
Fits inside the GV4 breaker
Front monted external kit for GV4
Side monted external kit for GV4
Open door shaft operator to comply with UL508
Suitable for GV7
      Characteristics
NC (fault) + NO
NC (fault) + NO
NC (fault) + NO
Instantaneous auxiliary contact
Instantaneous auxiliary contact
Instantaneous auxiliary contact
Instantaneous auxiliary contact with spring terminals
Instantaneous auxiliary contact with spring terminals
Fault signalling contact + instantaneous contact
Short circuit signalling contact
Instantaneous auxiliary contact
Instantaneous auxiliary contact
Instantaneous auxiliary contact with spring terminals
Instantaneous auxiliary contact with spring terminals
Auxiliary contact for OF (Open/ Close) or SD (trip) indication
Red/Yellow handle
Red/Yellow handle
-
Allows remote indication of breaker contact states.
Characteristics
Fits on LH side of GV2 or GV3
Fits on LH side of GV2 or GV3
Fits on LH side of GV2 or GV3
NO or NC ( depends how aux is mounted)
NO + NC
NO + NO
NO + NC
NO + NO
NO (fault) + NO
C/O common point
NO + NC
NO + NO
NO + NC
NO + NO
NO + NC
IP54
IP54
-
1c/o standard auxiliary contact
Part No.
GVAD0110
GVAD1001
GVAD1010
GVAE1
GVAE11
GVAE20
GVAE113
GVAE203
GVAED101
GVAM11
GVAN11
GVAN20
GVAN113
GVAN203
GV4AE11
GV4APN02
LV426936
LV426937
GV7AE11
 Can't see what you need? Our experts can help!
65
TeSys GV3/4-L
• 50kA fault rating at 400 volts
• EverLink terminals for a strong, safe long lasting power connection
• GV3 common accessories to the GV2 range
• Can be operated directly or via external operator
             Rotary Handle
  Tripping Current
560 amp tripping current
700 amp tripping current
910 amp tripping current
Adjustable 6...14 x In
Magnetic Protection Rating
40 amp magnetic protection rating
50 amp magnetic protection rating
65 amp magnetic protection rating
80 amp magnetic protection rating
Part No.
GV3L40
GV3L50
GV3L65
GV4L80N
           TeSys GV3/4
   Other Accessories
 Description
Laser square
Fits on RH side of GV2 or GV3
Fits on RH side of GV2 or GV3
Fits on RH side of GV2 or GV3
Fits on RH side of GV2 or GV3
Fits on RH side of GV2 or GV3
Fits on RH side of GV2 or GV3
Fits on RH side of GV2 or GV3
Sealing kit for enclosure front plate
Red mushroom head stop pushbutton
Red mushroom head stop pushbutton
Double insulated surface mounted enclosure
Double insulated surface mounted enclosure
Double insulated surface mounted enclosure with e stop button fitted
Double insulated flush mounted enclosure
Padlocking device for GV2ME
Set of 115A busbars
Terminal shield
Phase barrier
Extended rotary handle
Direct rotary handle
Direct rotary handle
Characteristics
Tool to facilitate allignment of external rotary handle
Undervolage trip
Undervolage trip
Undervolage trip
Undervolage trip
Undervolage trip
Shunt trip
Shunt trip
IP55
IP55
IP55
IP41
IP55
IP55
IP41
1 to 3 padlocks
For parallelling of contactors
IP405
Used when fitting shield is impossible
Red handle, yellow legend
Black handle , black legend
Red handle, yellow legend
-
110 - 115v 50Hz
220 - 240v 50Hz
220 - 240v 60Hz
380 - 400v 50Hz
415 - 440v 50Hz
380 - 400v 50Hz
415 - 440v 50Hz
5 to 40 degree temperatures
Key release
Turn to release
For GV2ME
For GV2ME
For GV2ME
For GV2ME
-
Suitable for D40A to D65A
-
-
IP55
IP40
IP40
Part No.
GVAPL01
GVAU115
GVAU225
GVAU226
GVAU385
GVAU415
GVAS385
GVAS415
GV2E01
GV2K021
GV2K04
GV2MC01
GV2MC02
GV2MCK04
GV2MP01
GV2V03
GV3G264
GV7AC01
GV7AC04
GV7AP02
GV7AP03
GV7AP04
             Rotary Handle
  Tripping Current
252 amps magnetic trip current
350 amps magnetic trip current
448 amps magnetic trip current
560 amps magnetic trip current
700 amps magnetic trip current
910 amps magnetic trip current
13x thermal settings
13x thermal settings
12 to
17 to
23 to
30 to
37 to
48 to
40 to
65 to
Thermal Setting Range
18 amps thermal setting range
25 amps thermal setting range
32 amps thermal setting range
40 amps thermal setting range
50 amps thermal setting range
65 amps thermal setting range
80 amps thermal setting range
115 amps thermal setting range
Part No.
GV3P18
GV3P25
GV3P32
GV3P40
GV3P50
GV3P65
GV4P80N
GV4P115N
                   CONTROL