Page 318 - Lockwell Industrial Catalogue
P. 318
DIGITAL MULTIMETERS
Fluke 170 Series Digital Multimeters
Fluke 110 Series Digital Multimeters
The Fluke 117 Digital Multimeter includes integrated non-contact voltage detection to help get the job done faster. The Fluke 115 Digital Multimeter is the solution for a wide variety of electrical and electronic testing applications. The Fluke 116 Digital Multimeter was specifically designed for the HVAC professional. The Fluke 114 Digital Multimeter is the best troubleshooting tool for “go/no-go” testing and the 113 is a basic electrical and utility multimeter.
Features and benefits
• • • •
•
AutoVolt feature for automatic ac/dc voltage selection (117, 116, 114) Min/Max/Avg to record signal fluctuations
Large display and white LED backlight to work in poorly lit areas more effectively Built in thermometer for HVAC applications (116)
Accessories - Fluke C50 case
Specification
AC/DC Voltage
AC/DC Current
Resistance
Capacitance
Fluke 117
600 V
10 A
40 MΩ
1 nF to 9,999μF
Fluke 116
600 V
600.0 μA
40 MΩ
1 nF to 9,999μF
Fluke 115
600 V
10 A
40 MΩ
1 nF to 9,999μF
Fluke 114
600 V
-
40 KΩ
-
-
-
-
Fluke 113
600 V
-
60 KΩ
-
↓
-
-
Maintenance experts can find most electrical and HVAC problems The Fluke 170 Series True-rms Multimeters are simple to use with significant improvements over the original Fluke 70 Series.
Features and benefits
• Wide 1000 V measurement range
• True-rms for precise measurement of non-linear signals
• Capacitance,resistance,continuityandfrequency
• Basic DC accuracy - 0.09%
• Backlit display
• Built-in thermometer (Fluke 179 only)
• Min/Max/Avg to record signal fluctuations
• Displayholeandautohold
• Manualandautomaticranging
• Accessories - Fluke C90 Case
Specification
DC voltage ± 0.09 %
AC voltage1
DC current
AC current2
Resistance
Capacitance
Frequency3
Temperature (179 only)
Range
600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V
600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V
60.00 mA, 400.0 mA, 6.000 A, 10.00 A2
60.00 mA, 400.0 mA, 6.000 A, 10.00 A2
600.0 W, 6.000 kW, 60.00 kW, 600.0 kW, 6.000 MW, 50.00 MW
1000 nF, 10.00 μF, 100.0 μF, 9999 μF
99.99 Hz, 999.9 Hz, 9.999 kHz, 99.99 kHz
-40 oC to +400 oC (-40 oF to +752 oF)
Resolution
± 0.09 %
± 1.0 % of reading
± 1.0 % of reading
± 1.5 % of reading
± 0.9 % of reading
± 1.2 % of reading
± 0.1 % of reading
1.0 % of reading
Diodetest ↓ - ↓
Frequency
Temperature
Safety rating
5 Hz TO 99.99 kHz
-
5 Hz TO 99.99 kHz
+400 °C
5 Hz TO 99.99 kHz
-
1 All ac voltage and ac current ranges are specified from 5 % of range to 100 % of range.
2 10 A continuous, 20 A for up to 30 seconds.
3 Voltage frequency is specified from 2 Hz to 100 kHz. Current frequency is specified from 2 Hz to 30 kHz.
CAT III 600 V
CAT III 600 V
CAT III 600 V
CAT III 600 V
CAT IV 600 V
318
TEST INSTRUMENTS