 TF96 thermal overload relays – 40.0 to 96.0 A
Ordering details
TF96
– Manual or automatic reset selectable
– Phase loss sensitive acc. to IEC/EN 60947-4-1
– TEST and STOP function – Trip indication on the front – Temperature compensation
– Suitable for three- and single-phase applications
– With ATEX certification 1)
Ordering details
Setting range
Description
The TF96 thermal overload relays are economic electromechanical protection devices for the main circuit. They offer reliable protection for motors in the event of overload or phase failure. The devices have trip class 10.
The thermal overload relays are three pole relays with bimetal tripping elements. The motor current flows through the bimetal tripping elements and heats them directly and indirectly. In case of an overload (over current), the bimetal elements bent as a result of the heating. This leads to a release of the relay and a change of the contacts switching position (95-96 / 97-98).
          Short-circuit protective device
     Trip class
       Type
     Order code
                    125 A, gG Type Fuses
           10
         TF96-51
            1SAZ911201R1001
                         160 A, gG Type Fuses
10
  TF96-60
  1SAZ911201R1002
                 160 A, gG Type Fuses
 10
          TF96-68
   1SAZ911201R1003
                           200 A, gG Type Fuses
           10
             TF96-78
              1SAZ911201R1004
                             200 A, gG Type Fuses
10
  TF96-87
  1SAZ911201R1005
                  250 A, gG Type Fuses
    10
            TF96-96
      1SAZ911201R1006
                   A                       kg
Weight
(1 pce)
                                   DB96
40.0 ... 51.0 48.0 ... 60.0 57.0 ... 68.0 65.0 ... 78.0 75.0 ... 87.0 84.0 ... 96.0
Ordering details accessories
Suitable for
TF96, EF96
0.620 0.620 0.620 0.620 0.620 0.630
Weight (1 pce) kg 0.190
     Description
           Type
        Order code
                    Single mounting kit
            DB96
          1SAZ901901R1001
                     Reset push button 2)
  KPR-101L
   1SFA616162R1014
               TF96                     0.027
1) ATEX is valid for products, produced from week 26, 2015
2) Note: for more information see catalog 1SFC151004C0201
  DB96 + TF96
KPR-101L
 Can't see what you need? Our experts can help!