POWERPACT 4 PANELBOARDS ACCESSORIES FOR USE WITH ACCESSORIES POWERPACT 4 PANELBOARDS
AND COMPACT NSX MCCBS
Outgoing Pan Assembly
Pan assemblies provide easy to connect high density connection independent of device mix for mounting of moulded case circuit breakers into a low voltage power distribution switchboard. Can be fed from the side or bottom fed using incoming pan assembly.
SP ways
18
36
54
72
90
Reference for 630A busbar Reference for 800A busbar
MG6PAC6 MG8PAC6
MG6PAC12 MG8PAC12
MG6PAC18 MG8PAC18
MG6PAC24 MG8PAC24
MG6PAC30 MG8PAC30
Ammeter
18 way neutral bar kit
Mounts on either side of incoming device when using incoming pan assembly. Includes disconnectable neutral link.
Type
630A
800A
Reference
MG6PANKIT
MG8PANKIT
3 phase ammeter complete with CT’s (mounted on the breaker). Can be fitted on incoming or outgoing device.
Current Rating
NSX100
NSX160
NSX250
NSX400
NSX630
Number of Poles
3P
3P
3P
3P
3P
Reference
LV429455
LV430555
LV431565
LV432655
LV432855
Shrouding Kit
Provides additional support for device and shrouding for front cover. One shrouding kit must be used per side when fitting either outgoing 400/630Amp MCCBs or outgoing ammeter and/or earth leakage protection. In addition to the shrouding
kit an additional 25mm three stage filler piece is required when 4 pole 400A or 630A circuit breakers are fitted on the outgoing pan assembly MGPTSF25.
Number of outgoing ways SP
18
36
54
Number of outgoing ways TP
6
12
18
Reference
MGPCH6
MGPCH12
MGPCH18
Current Transformer Module
Single Pole Shrouding Plates
MGPBBP
Single pole shrouding plates are required for each unoccu- pied outgoing way.
MGPBB25
In addition a 25mm shrouding plate is always required when 4 pole 400A or 630A circuit breakers are mounted on the outgoing pan assembly.
Boards up to 800A are supplied with 3 x MGPBBP. 160AA board is supplied with 6 x MGPBBP.
HERE TO HELP...
LOCKWELL OFFER A VARIETY OF INVENTORY SAVING OPTIONS SUCH AS CONSIGNMENT STOCK, DEDICATED STOCK AND VENDOR MANAGED; PLEASE CALL YOUR LOCAL BRANCH FOR MORE INFORMATION
3 phase current transformer module.
Fits directly on the terminals of the breaker.
Breaker
CT Ratio
VA output
1.6
3.0
5.0
8.0
8.0
Class at VA output
3.0
3.0
3.0
3.0
3.0
Reference 3 Pole
LV429457
LV430557
LV431567
LV432657
LV432857
NS100 125/5
NS160 150/5
NS250 250/5
NS400 400/5
NS630 600/5
Rotary handles with inbuilt padlocking facilities
Current Rating
Up to 250A
400/630A
Colour
Black
Black
Reference
LV429337
LV432597