    WAGO SIGNAL CONDITIONING & MONITORING
   JUMPFLEX
WAGO’s Jumpflex signal conditioners come in two form types, 857 (6mm wide, up to 3Kv isolation) & 2857 (12.5 mm wide, up to 4KV isolation), and all benefit from WAGO’s famous push-in cage clamp connections.
• Compatibility (jumpering) with 857 range of relays
• Safe isolation and extended temperature range
• Calibrated configurable signals
• Configurationoptions(DIPswitch,push-
slide/PC or Jumpflex to go App)
• -25 to +70°C
• Capacitivetouchscreen(2857range)
• Pluggableconnections‘picoMAX’(2857)
• Isolation amplifier with auto reset fuse
• Laser trimmed resistors for consistent accuracy
• Clipping function to limit analogue signals
• Multitudeoffunctions
• Approvals ATEX, IEC-Ex, Marine, UL
 WAGO Part Number
857-400
857-531
857-401
857-402
857-451
857-815
857-819
857-423
857-424
2857-550
2857-533
2857-900
750-921
750-923/000-001
Type
Signal Conditioning
Signal Conditioning / Monitoring
Signal Conditioning / Monitoring
Signal Conditioning
Signal Conditioning
Signal Conditioning
Signal Conditioning
Signal Conditioning
Signal Conditioning
Signal Conditioning / Monitoring
Signal Conditioning / Monitoring
Signal Conditioning Accessory
Signal Conditioning Accessory
Signal Conditioning Accessory
Function
Conversion / Isolation Amp with Zero Span
Threshold Value Relay Output, Standard Analogue Input
Conversion / Isolation Amplifier with Digital Output
Universal Isolation Amplifer
Passive Isolator 1 Channel
Loop Powered RTD Temperature Transmitter
Millivolt Signal Conditioner Convert to Analogue Standard Signal
Signal Splitter with 2 Configurable Current Outputs
Signal Splitter with 2 Configurable Current or Voltage Outputs
Current Signal Conditioner AC/ DC 100A
RTD Sensor Temperature Threshold Switch
Capacitive Touchscreen, Configuration Display
Bluetooth Module
USB Cable
Description
The configurable isolation amplifier converts, amplifies, filters and electrically isolates Analogue standard signals.
Zero/span adjustment across the entire measuring range.
Switching between measuring ranges is calibrated.
Switchable max. operating frequency.
Safe 3-way isolation with 2.5 kV test voltage acc. to EN 61140.
The threshold value switch for analogue signals monitors analog standard signals and reports signals exceeding a preset threshold.
PC configuration interface.
Digital switching output.
Changeover contact relay output.
Calibrated measurement range switching.
Threshold value configuration via DIP switches and teach-in function via push/slide switch. Safe 3-way isolation with 2.5 kV test voltage acc. to EN 61140.
The configurable isolation amplifier converts, amplifies, filters, and electrically isolates standard analogue signals.
PC configuration interface.
Digital switching output.
Calibrated measurement range switching.
Analog, unipolar, and bipolar (standard) signals at input.
Switchable clipping capability limits the standard analog signal to the upper range values. Safe 3-way isolation with 2.5 kV test voltage acc. to EN 61140.
The universal isolation amplifier converts unipolar and bipolar standard signals and amplifies, filters and electrically isolates analog standard signals.
Input overcurrent protection via resettable fuse.
Zero/span adjustment across the entire measuring range (push/slide switch).
Calibrated measuring range switching for all signals.
Analog, unipolar and bipolar, standard signals at input/output.
Switchable max. operating frequency.
Clipping capability allows analogue standard signal limitation to upper range values. Safe 3-way isolation with 2.5 kV test voltage acc. to EN 61140.
The 1-channel passive isolator filters and electrically isolates 0(4)–20 mA analogue standard signals, while drawing power for signal transmission from the input circuit. The connected sensor supplies the passive isolator with the required -power, while powering the connected load.
No additional supply voltage required
Safe 3-way isolation with 2.5kV test voltage acc. to EN 61140
The loop-powered RTD temperature transmitter is used to acquire Pt100, Pt200, Pt500 and Pt1000 sensors and resistors up to 4.5 kOhms and converts the temperature signal on the output side into an analogue standard signal.
No additional supply voltage necessary.
For Pt100, Pt200, Pt500 and Pt1000 sensors and resistors up to 4.5 kOhm. 2-, 3- and 4-wire connection technology.
Calibrated range switching.
Detection: wire break / short circuit of the sensor.
Safe 3-way isolation with 2.5kV test voltage according to EN 61010-1.
The Millivolt Signal Conditioner converts input millivolt signals into standard analogue signals on the output side.
PC configuration interface.
Calibrated measurement range switching.
Switchable clipping capability limits the standard analog signal to the upper range values Safe 3-way isolation with 2.5 kV test voltage acc. to EN 61140.
The signal splitter converts, amplifies, filters and electrically isolates analogue standard signals. Two configurable current outputs.
Switching between measuring ranges is calibrated.
Switchable max. operating frequency.
Safe 4-way isolation with 2.5 kV test voltage acc. to EN 61140.
The signal splitter converts analog standard signals, amplifies, filters and separates the analogue standard signals galvanically from each other. In addition, the input signal is split to two separate outputs.
2 configurable voltage / current outputs.
Switchable max. operating frequency.
Safe 4-way isolation with 3kV test voltage according to EN 61010-1.
The 2857-550 Current Signal Conditioner measures AC/DC currents up to 100 A, while converting the measured current into an analogue standard signal at the output.
Both digital signal output and relay with changeover contact react to configured measuring range limits (switching ON/OFF delay and threshold value switch function configurable with up to two threshold values).
Clipping capability provides analog signal limitation to output end values. Adjustable software filter.
Input/Output response simulation via configuration display.
Safe 3-way isolation with 4 kV test voltage acc. to EN 61010-1.
WAGO's RTD Threshold Value Switch for RTD sensors, potentiometers and resistors monitors and reports signals of up to two switching thresholds.
Both digital signal output and relay with make contact react to configured measuring range limits (switching ON/OFF delay and threshold value switch function configurable with up to two threshold values).
Configurable RTD factor.
Adjustable software filter.
Input/Output response simulation via configuration display. Safe 3-way isolation with 4 kV test voltage acc. to EN 61140.
Programming touchscreen for 2857 series, has save / restore function for parameters.Easy mounting on 2857 Series devices.
Automatic module detection.
Capacitive user interface with slider function.
Intuitive menu navigation.
Color backlight for status indication.
Device configuration and process value visualisation. Easy copying of device configuration.
The Bluetooth® Adapter wirelessly connects to PC / Android App with Bluetooth® functionality to the service interface of the buscoupler/controller.
The WAGO USB Communication Cable connects a PC (notebook) to either the service interface of the 857 Series Signal Conditioners and Relay Modules (JUMPFLEX), or to WAGO-I/O-SYSTEM buscouplers/controllers.